- Opening : Mon-Fri 08:00 - 17:00
Product
Category COMBINERS
HC04CH-FM
Features
Compact passive combiner for up to 4 input sources.
Useful for all those transmission inside tunnels or closed environments, with the possibility of transmission on slotted cable.
HC04CH-FM | |||
Parameters | U.M. | Value | |
GENERALS | |||
Frequency range | Mhz | 87.5 ÷ 108 | |
Rated output power | W | 150 | |
Unbalanced Power Limit | W | 150 | |
Ambient working temperature | °C | -50 to +50 | |
Ambient working humidity | % | 85 (Without condensing) | |
INPUTS | |||
Power Coupler | Connector | N | |
Impedance | Ohm | 50 | |
Number of Way | 4 | ||
Power | W | 150 | |
Insertion Loss | dB | 6 | |
OUTPUTS | |||
Power coupler | Connector | N | |
Impedance | Ohm | 50 | |
POWER REQUIREMENTS | |||
AC Power Input | AC Supply Voltages | VAC | 230 + 10% – 15% |
AC Apparent Power Consumption | VA | 48 | |
Active Power Consumption | W | 48 | |
Power Factor | 0,998 | ||
Connector | VDE IEC Standard | ||
DC Power Input | DC Supply Voltage | VDC | — |
DC Current | ADC | — | |
MECHANICAL DIMENSIONS | |||
Phisical Dimensions | Front panel width | mm | 483 (19”) |
Front panel height | mm | 132 (3HE) | |
Overall depth | mm | 557 | |
Chassis depth | mm | 485 | |
Weight | kg | About 10 | |
VARIOUS | |||
Cooling | Forced, with internal fan | ||
Acoustic Noise | dBA | <75 | |
AUXILIARY CONNECTIONS | |||
Interlock 1 | Connector | BNC | |
Interlock 2 | Connector | BNC | |
R.F. Monitor 1 | Connector | BNC | |
R.F. Monitor 2 | Connector | BNC | |
FUSES | |||
On Mains | 1 External F 3,15 – 5×20 mm |